Bottled Water Cooler Specifications

  • Cabinet: All corrosion-resistant stainless steel type-316L, inside and outside including interior shelves, mountings and drip basin. Satin finish on all exterior surfaces for an attractive and easily-cleaned lustrous appearance. Bottle-support ring made of durable and corrosion-resistant polypropylene.

  • Valves: Self-closing, no-drip cup filler. Made from durable and corrosion-resistant polypropylene.

  • Cold Water Reservoir: Flat-bottom stainless steel basin with approximately 2-1/2 quarts (2.4 liters) useable capacity and polypropylene fittings. Corrosion-protected copper evaporator coil is wrapped around reservoir, insulated with closed-cell elastomer and bonded to basin with thermal mastic.

  • Corrosion Protection: Capillary tube, sight glass, filter-dryer, two access valves and all metal tubing protected by coating of high-solids special low-porosity epoxy applied by immersing assemblies in an electrostatically-charged bath and cured by baking in an oven to protect them from acidic, caustic, saline, and other types of corrosion.

  • Condenser: Triple layer and sized for high ambient temperatures and high altitudes, and protected against acidic and other corrosion with a special epoxy coating (e-coat) with near-zero porosity applied electrostatically and oven cured.

  • Compressor: Andover Protection Systems’ Model EEG (for 115/60/1) or APS Model EEJ (220-240/50-60/1). These compressors are specifically designed for use in harsh or harsh and hazardous conditions.

  • Capacity:

    • Rated Capacity: At water and air temperature of 131º F (55C)— lower 0.5 gallon (1.9 liters) per hour of water from 131ºF (55C) to 50ºF (10C) – Note: 131ºF water will scald skin; therefore, chiller must lower the water 81ºF (27C) degrees to reach the standard chilled-water temperature of 50ºF (10C).

    • Capacity at ARI standard conditions: water and air temperature of 90ºF (32.2C)—lower 0.9 gallons (3.4 liters) per hour of water from 90ºF (32.2C) to 50ºF (10C) -- (50% more cold water than standard units)

  • ADA: Overall, the coolers comply with the requirements of the ADA specification 4.15.2-4

  • Shipping Dimensions: Approximately 80 pounds and 6.5 cubic feet.

  • Hazardous-Duty: When specified, BSDE makes the units suitable for hazardous-duty ("explosion-proof") conditions. It will use UL-recognized hazardous-duty compressors appropriate for the classification of the area. BSDE offers bottled-water coolers suitable for use in areas classified for any of the following types of locations: Class I, II, or III, Groups B, C, D, E, F or G, and Division/Zone 2 or 1. The units will be factory sealed for fast and easy installation. The hazardous-duty units will have the standard harsh-duty features of BSDE's standard coolers.