MODEL
|
Nominal
Cooling
Capacity
(BTUH) |
Rated
Volts/
Hz/
Phase |
CONDENSER |
EVAPORATOR |
Amperes
(Cooling
Operations) |
Fan |
Net
Weight
(Approx)
(pounds) |
Ship
Weight
(Approx)
(pounds) |
Amperes
(Cooling
Operations) |
Amperes
(Heating
Operations) |
Fan |
Heating |
Net
Weight
(Approx)
(pounds) |
Ship
Weight
(Approx)
(pounds) |
CFM
High
Med
Low |
RPM
High
Med
Low |
CFM
High
Med
Low |
RPM
High
Med
Low |
(BTUH) |
(Watts) |
| ASC-12AV-*+ |
12000 |
230-208/60/1 |
7.0/7.7 |
510/460/400 |
1000/920/810 |
128 |
140 |
1.8/2.0 |
|
510/460/400 |
1000/920/810 |
|
|
91 |
109 |
| ASC-12AA-*+ |
12000 |
115/60/1 |
14.7 |
510/460/400 |
1000/920/810 |
128 |
150 |
3.7 |
|
510/460/400 |
1000/920/810 |
|
|
91 |
109 |
| ASC-18AV-*+ |
18000 |
230-208/60/1 |
7.5/8.3 |
625/560/480 |
1030/975/900 |
160 |
176 |
1.8/2.0 |
|
625/560/480 |
1030/975/900 |
|
|
96 |
114 |
| ASC-24AV-*+ |
24000 |
230-208/60/1 |
10.2/11.1 |
780/700/630 |
1100/1050/1000 |
167 |
183 |
1.8/2.0 |
|
780/700/630 |
1100/1050/1000 |
|
|
99 |
117 |
| ASC-30AV-*+ |
30000 |
230-208/60/1 |
13.2/14.5 |
780/700/630 |
1100/1050/1000 |
174 |
190 |
1.8/2.0 |
|
780/700/630 |
1100/1050/1000 |
|
|
99 |
117 |
| ASC-36AV-*+ |
36000 |
230-208/60/1 |
16.7/18.4 |
1100/900/725 |
1550/1300/1050 |
191 |
207 |
1.8/2.0 |
|
1100/900/725 |
1550/1300/1050 |
|
|
109 |
127 |
| ASCH-12AV-*+ |
12000 |
230-208/60/1 |
7.0/7.7 |
510/400 |
1000/810 |
128 |
150 |
1.8/2.0 |
17.6/19.4 |
510/400 |
1000/810 |
13,652/11,165 |
4000/3270 |
91 |
109 |
| ASCH-18AV-*+ |
18000 |
230-208/60/1 |
7.5/8.3 |
625/500 |
1030/900 |
160 |
176 |
1.8/2.0 |
17.6/19.4 |
625/500 |
1030/900 |
13,652/11,165 |
4000/3270 |
96 |
114 |
| ASCH-24AV-*+ |
24000 |
230-208/60/1 |
10.2/11.1 |
830/780 |
1100/1000 |
167 |
183 |
1.8/2.0 |
17.6/19.4 |
830/780 |
1100/1000 |
13,652/11,165 |
4000/3270 |
99 |
117 |
| ASCH-30AV-*+ |
30000 |
230-208/60/1 |
13.2/14.5 |
830/780 |
1100/1000 |
174 |
190 |
1.8/2.0 |
17.6/19.4 |
830/780 |
1100/1000 |
13,652/11,165 |
4000/3270 |
99 |
117 |
| ASCH-36AV-*+ |
36000 |
230-208/60/1 |
16.7/18.4 |
1100/900 |
1550/1050 |
191 |
207 |
1.8/2.0 |
35.2/38.8 |
1100/900 |
1550/1050 |
27,304/22,330 |
8000/6540 |
109 |
127 |
|
When ordering hazardous-duty units, must specify classification of area
(Class, Group(s) and Division/Zone) |
| *
When specifying model, substitute Group name (B, C, D, E, F or G) for the
asterisk (*) symbol |
| +
When specifying model, substitute Division/Zone 1 or 2 for plus (+) symbol |
| Information above applies Division/Zone 2 units; consult factory for characteristics of
Division/Zone 1 models. |
| Most units can be used without
modification at 220-200/50/1 at reduced capacity and with modification at 240-220/50/1 |
| Generally units have the same
height and width: 16-3/4" (43 cm) high by 26-1/2" (67 cm) wide
by 31" (79 cm) deep |
|