MODEL
Nominal
Cooling
Capacity
(BTUH)
Rated
Volts/
Hz/
Phase

CONDENSER

EVAPORATOR

Amperes
(Cooling
Operations)

Fan

Net
Weight
(Approx)
(pounds)
Ship
Weight
(Approx)
(pounds)
Amperes
(Cooling
Operations)
Amperes
(Heating
Operations)

Fan

Heating

Net
Weight
(Approx)
(pounds)
Ship
Weight
(Approx)
(pounds)
CFM
High
Med
Low
RPM
High
Med
Low
CFM
High
Med
Low
RPM
High
Med
Low
(BTUH) (Watts)
ASC-12AV 12000 230-208/60/1 7.0/7.7 510/460/400 1000/920/810 118 130 1.8/2.0 510/460/400 1000/920/810 81 99
ASC-12AA 12000 115/60/1 14.7 510/460/400 1000/920/810 118 130 3.7 510/460/400 1000/920/810 81 99
ASC-18AV 18000 230-208/60/1 7.5/8.3 625/560/480 1030/975/900 150 166 1.8/2.0 625/560/480 1030/975/900 86 104
ASC-24AV 24000 230-208/60/1 10.2/11.1 780/700/630 1100/1050/1000 157 173 1.8/2.0 780/700/630 1100/1050/1000 89 107
ASC-30AV 30000 230-208/60/1 13.2/14.5 780/700/630 1100/1050/1000 164 180 1.8/2.0 780/700/630 1100/1050/1000 89 107
ASC-36AV 36000 230-208/60/1 16.7/18.4 1100/900/725 1550/1300/1050 181 197 1.8/2.0 1100/900/725 1550/1300/1050 99 117
ASCH-12AV 12000 230-208/60/1 7.0/7.7 510/400 1000/810 118 130 1.8/2.0 17.6/19.4 510/400 1000/810 13,652/11,165 4000/3270 85 103
ASCH-18AV 18000 230-208/60/1 7.5/8.3 625/500 1030/900 150 166 1.8/2.0 17.6/19.4 625/500 1030/900 13,652/11,165 4000/3270 90 108
ASCH-24AV 24000 230-208/60/1 10.2/11.1 830/780 1100/1000 157 173 1.8/2.0 17.6/19.4 830/780 1100/1000 13,652/11,165 4000/3270 93 111
ASCH-30AV 30000 230-208/60/1 13.2/14.5 830/780 1100/1000 164 180 1.8/2.0 17.6/19.4 830/780 1100/1000 13,652/11,165 4000/3270 93 111
ASCH-36AV 36000 230-208/60/1 16.7/18.4 1100/900 1550/1050 181 197 1.8/2.0 35.2/38.8 1100/900 1550/1050 27,304/22,330 8000/6540 107 125
Information above applies to non-hazardous-duty and Division/Zone 2 units; consult factory for characteristics of Division/Zone 1 models.
Most units can be used without modification at 220-200/50/1 and with modification at 240-220/50/1
Dimensions--Condensers: 16-1/8" (41 cm) High X 26-5/8" (68 cm) Wide X 19" (48 cm) Deep
Evaporators: 16-3/4" (42.5 cm) High X 26-5/8" (68 cm) Wide X 14-1/2" (37 cm) Deep
If ordering hazardous-duty units, must specify classification of area (Class, Group and Division/Zone)